QBCC Licence 1213114 Warwick base, SW & SE QLD Mon to Fri, 7am to 4pm
(07) 4661 1116
Total Fire Protection ServiceWarwick QLD
A serviced fire extinguisher with its current maintenance tag attached

Servicing

How often do fire extinguishers need servicing in Queensland?

Six months is the short answer. The longer answer is what actually happens at each visit, why the five-year test catches people out, and what your records have to look like when someone asks for them.

Portable fire extinguishers in a Queensland commercial building are serviced every six months. That interval comes from AS 1851-2012, the Australian Standard for the routine service of fire protection systems and equipment, which the Building Fire Safety Regulation 2008 points to as the benchmark for maintaining prescribed fire safety installations.

Two visits a year, roughly six months apart. Miss one and the tag on the unit goes out of date, which is the first thing an inspector, an insurer or an auditor looks at, because it is the easiest thing in the building to check.

What actually happens at a six-monthly service

It is not a glance and a signature. On each unit the technician works through the same list:

  • Location and access. The extinguisher is where the plan says it is, it is visible, the sign above it is there, and nothing has been stacked in front of it. This is the single most common failure we write up, and it is always free to fix.
  • Pressure. The gauge needle sits in the green. A unit that has crept into the red or drifted below the operating range comes out of service.
  • Physical condition. Dents, corrosion, a damaged hose, a cracked or perished nozzle, a seized handle. Anything that would stop it working when someone pulls the pin.
  • Seals and pin. Both intact. A broken tamper seal means the unit has been operated or interfered with, and it gets a full check rather than a visual one.
  • Weight. Units are weighed against their charged weight so a slow loss of agent shows up before the gauge does.
  • The record. The service tag on the unit is updated and the same entry goes onto the asset register for the building.

Dry chemical units also get their contents checked for compaction. ABE powder can settle into a solid cake in a unit that has sat on a bracket in a hot workshop for years, and a caked unit will not discharge properly no matter what the gauge says.

The intervals that matter

  • Six months. Routine service and inspection of every portable extinguisher, under AS 1851-2012.
  • Five years. Most units come off the wall for a pressure test, discharge and refill. Some types are on a different cycle, and a few are replaced rather than tested.
  • Immediately after use. A discharged extinguisher is refilled or replaced. A half-used unit on a bracket is worse than no unit, because someone will reach for it.
  • Twelve months. Your occupier's statement is due, and it covers every one of these installations at once.

The five-year test is the one that surprises people

Every six months the extinguisher is checked in place. Every five years most units are taken away, depressurised, internally inspected, pressure tested, refilled and recertified, or replaced if the shell no longer passes. The date of that test is stamped or written on the unit.

The reason it catches businesses out is timing. A building fitted out ten years ago got all of its extinguishers at once, so they all fall due at once. That turns into a bigger invoice in one year than the owner budgeted for, and the temptation is to push it out. It is not something you can push out. Once a unit is past its test date it is not compliant, and it will be written up on the next audit.

If you are heading into one of those years, tell us early and we will stage the work across the schedule rather than doing it in one hit.

What your records have to show

The equipment being serviced is only half of it. The other half is being able to prove it. For each prescribed installation you need a maintenance record that shows what was inspected, when, by whom, what was found and what was done about it, and those records need to be available at the building.

In practice that means an asset register: every extinguisher listed with its type, size, location, serial number, last service and next due date. When we take on a building the first visit usually involves building that register from scratch, because either it does not exist or it went with the last contractor. Once it exists, everything after it is straightforward, and your annual occupier's statement becomes a formality rather than a scramble.

What this looks like with us

Your building goes on a schedule, we turn up when the six months is due rather than waiting for you to remember, and you get the paperwork the same week. If a unit fails, we tell you what it costs to fix before we do it. Ask for a quote or call (07) 4661 1116.

Who is responsible, the owner or the tenant?

It depends on the lease, and the two parties often assume it is the other one. The Building Fire Safety Regulation puts the duty on the occupier of the building, which in a leased commercial premises is usually the tenant. Many leases then pass the cost of maintaining fire equipment back to the landlord, or split it between base building systems and tenancy equipment.

Whatever the lease says, the practical answer is the same: someone has to be booking the service, and if neither party is sure, nobody is. If you have taken on a tenancy and cannot find a service history, that is the moment to get someone through the building.

Does it have to be a licensed contractor?

The work has to be done by a competent person, and the person signing off on it has to be able to stand behind it. We hold QBCC licence 1213114 and are an FPA Australia Bronze Member, and every service we do is recorded against the standard it was done to. If you are comparing quotes, the thing worth checking is not the price per unit, it is whether you get a written record you can hand to an auditor at the end of it.

The short version

Six-monthly service, five-yearly pressure test, records kept at the building, and an occupier's statement once a year that ties it all together. It is not complicated, but it does not look after itself, and the businesses that get caught out are almost always the ones where nobody owned the calendar.

Written from the workshop at 96-98 Grafton Street, Warwick. General information only, not a substitute for advice on your own building. For a straight answer on your premises, give us a call.

All fire safety advice

Keep reading

More from the workshop

Common questions

Questions we
get asked

If yours is not answered here, ask us on the phone. We would rather sort it out before you book than after.

How often do fire extinguishers need to be serviced in Queensland?

Every six months. AS 1851-2012 sets a six-monthly routine service for portable fire extinguishers, and the Building Fire Safety Regulation 2008 requires prescribed fire safety installations in Queensland buildings to be maintained to that standard.

What is the five-year fire extinguisher test?

At five years most extinguishers are removed, depressurised, internally inspected, pressure tested, refilled and recertified, or replaced if the cylinder no longer passes. The date is marked on the unit, and a unit past its test date is not compliant.

Who is responsible for servicing fire extinguishers in a leased building?

The Building Fire Safety Regulation 2008 places the duty on the occupier of the building, which in a commercial tenancy is usually the tenant, though many leases pass the cost back to the owner. Whichever way your lease reads, someone has to be booking the service.

Do I need records of fire extinguisher servicing?

Yes. You need maintenance records showing what was inspected, when, by whom, what was found and what was done, and they need to be available at the building. In practice that is an asset register listing every unit with its type, location, last service and next due date.

Due for a service, or not sure when you last had one?

We will come through the building, list what is there, tell you what is due and quote it. Warwick based, across South West and South East Queensland.